SIMULATION OF OSL AND TLD DOSEMETER RESPONSE FOR THE DEVELOPMENT OF NEW EXTREMITY DOSEMETERS H Hoedlmoser H Hoedlmoser Individual Monitoring Service Helmholtz Zentrum München German Research Center for Environmental Health GmbH Otto-Hahn-Ring 6 München Germany Corresponding author. However the only change required in the irradiation procedure is the irradiation dose.


Brand New New Logo Identity And Livery For Air Arabia By Interbrand Brand Structure Air Arabia Identity Logo

TLD technology is widespread in use of cumulative dose determinationbut it has vulnerability to environmental factorsOSL technology offers stability in environmentenergy response to a wide rangeBy comparison of principlesmethods and performance between TLD with OSLtheir respective features and application were discussed in this paper.

. In TLDs the trapped electrons are subsequently freed by stimulation with heat while OSL uses stimulation with light. After stimulation by light the detector releases the stored energy in the form of light ie it is stimulated to emit light. 22 However in general materials have clearly superior properties when used with either thermal or optical stimulation.

TLD was 9. For example Al 2 O 3 C has been used as both TLD and OSLD. Tests carried out with other electronic dosemeters revealed differences up to 20 versus TLD.

TLD Thermoluminescent Dosimeter A thermoluminescent dosimeter abbreviated as TLD is a passive radiation dosimeter that measures ionizing radiation exposure by measuring the intensity of visible light emitted from a sensitive crystal in. The technology is insensitive to external parameters such as dust heat or humidity. For the values of high.

Doses from TLDs may be easily obtained. In fact the categorization of materials into TLD vs OSLD is somewhat artificial because most materials can exhibit both TL and OSL signals. TLDs can measure a greater range of doses compared to film badges.

THE OSL PROCESS IS NOT UNLIKE TLD. In fact we donï½t expect users to be aware of the change at all. TLDs are easily reusable.

AWST-OSL-GD01 The dosimeter is based on OSL technology optically stimulated luminescence which is read with light stimulation. 34964 N The initial bearing on the course from TLD to OSL is 34964 and the compass direction is N. OSL badges are much more rugged.

Furthermore two diamond detectors were tested. OSL VS TLD. With dosemeters positioned outside the goggles and when TLD doses were 20 μSv the average difference OSL vs.

Generally speaking the crystals in a TLD dosimeter are more prone to being damaged by high or low temperatures sudden changes in temperature moisture and humidity. BOTH ARE BASED ON STIMULATED LUMINESCENCE. OSL dosimeters will require a dose of only 100 cGy.

OSL dosimeters are of more recent vintage than thermoluminescent dosimeters TLDs. The diamond detectors show strong dose rate dependence. HOWEVER OSL HAS SEVERAL ADVANTAGES OVER TLD.

As a result the average surface dose showed 085 mSv difference with 127 mSv for TLD and 212 mSv for OSLD while having 073 mSv difference for the average depth dose with 133 mSv for TLD and. TLDs can be read on site instead of being sent away for development. GBE GOT GBE BGO GBE SVG GBE AAL JNB OSL.

The setup and blocks for irradiation are similar to those used in the TLD program. Recently evaluated by Radiological Physics Center RPC for remote dosimetryypp application OSL dosimeters were irradiated in an acrylic mini- phantom Results indicated that the precision of OSL dosimeters is comparable to that provided by TLDs used for remote dosimetry Summary. The fourth concern our customers have when trying to decide between OSL and TLD is the ruggedness of the dosimeter.

WITH A MINIMUM REPORTABLE DOSE OF 1 MREM OSL IS MORE SENSITIVE THEN TLD. The energy response for angles of incidence of 0 and 60 of current BeOSL Hp10- Hp3- Hp007- and H10 dosemeters for photon radiation has been expressed in. This corresponds to an approximate flight time of 11h 24min.

OSLD and TLD are quite similar in that both dosimeters respond to the absorption of energy from ionizing radiation by trapping electrons that are excited to. OSL HAS PRECISION OF -1 MREM WHICH BEATS TLD. For intermediate doses doses in radiotherapy the response is supralinear.

However the OSL dose response for aluminum oxide is linear only for low doses. The light output measured with photomultipliers is a measure unit for the dose. Please pay attention to this change.

Disadvantages of TLDs Each dose cannot be read out more than once. Comparing OSL to TLD Dosimeters Can be re-read Typically measures down to 1 mrem Chronological AND cumulative reporting Rugged and durable Typically only measures down to 10 mrem Cumulative reporting only Easily damaged Cannot be re-read. Optically stimulated luminescence OSL and thermoluminescence TL are very similar the only difference is the manner in which the electrons are freed from their traps 4 electrons are freed from their traps.

For phantom measurements OSL dose values resulted in an average difference of 15 vs. OSL Whole Body Dosemeter Hp10 Hp007 Part number. The dosimeters are dose rate independent up to 4 10 9 Gys within 2 OSL and TLD and up to 15 10 9 Gys within 5 EBT films.

The readout process effectively zeroes the TLD.